CL2608

- Manual Quote
| PWR | 。 |
|---|---|
| ALARM | 。 |
| PU+ | ,+5V~+24V +24V PU- 。 |
| PU- | 。 |
| DR+ | ,+5V~+24V +24V PU- 。 |
| DR- | 。 |
| MF+ | ,+5V~+24V +24V PU- 。 |
| MF- | 。 |
| ALM | ,COM- 50mA。 |
| PEND/Z | /Z )。SW4 。 ,COM- 50mA。 |
| BRK | 100mA。 |
| COM- | 。 |
| +5V/GND | / |
| EZ+/EZ- | / |
| EB+/EB- | / |
| EA+/EA- | / |
| A+/A- | A+/A- |
| B+/B- | B+/B- |
| V+/V- | , 20VAC~80VAC or 30VDC-110VDC |
Description
Product Center Stepper Drivers
DUMMY
24816326412825651020254050100200PU/Rev40080016003200640012800256005120010002000400050008000100002000040000SW10ONONONONONONONONOFFOFFOFFOFFOFFOFFOFFOFFSW9ONONONONOFFOFFOFFOFFONONONONOFFOFFOFFOFFSW8ONONOFFOFFONONOFFOFFONONOFFOFFONONOFFOFFSW7ONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFSW6 OFFDefaultON3msOFF12msON40msSW5OFFOFFONONSW4PEND/Z OFF:PEND ON:Z SW3 OFF:CLOSE ON:OPEN SW2 OFF:CCW ON:CWSW1 OFF:PU&DR ON:CW&CCW
DUMMY
CL2608R communication-type closed-loop stepper driver manual (Chinese), V11.21 MB
Adopts a dedicated 32-bit motor control DSP chip and optimized closed-loop control technology
Input voltage 20–80 VAC or 30–110 VDC
Maximum continuous output current 6.0 A; drives size 60 and 86 closed-loop stepper motors
Input signal level compatible with 5–24 V; maximum pulse response frequency up to 500 kHz (factory default 200 kHz)
Differential inputs for pulse, direction and enable signals; supports differential, common-cathode and common-anode wiring
Common-cathode output signals: alarm, in-position, Z signal and brake control; in-position and Z signal configurable via DIP switch
Microstep DIP setting (200–51200); when all microstep switches are ON, any microstep value can be set from host software
DIP-selectable single/double pulse, open/closed-loop mode and command smoothing time
Protections: overvoltage, undervoltage, overcurrent and position deviation, etc.
10. Smooth operation with low motor noise, small overshoot and small position tracking error
The CL2608 pulse-type closed-loop stepper driver adopts the latest dedicated 32-bit motor control DSP chip and optimized closed-loop control technology. Intelligent current adjustment reduces motor vibration and heat for longer service life; high-speed torque falloff is far lower than ordinary open-loop drivers, greatly improving high-speed performance and torque utilization, hence machine efficiency and precision. Built-in in-position, alarm and brake output signals make monitoring and control easy, and the position deviation alarm ensures safe operation of processing equipment. Two 10-position DIP switches support multiple common functions including single/double pulse, open/closed-loop mode selection and command smoothing time, making commissioning easier. Committed to providing customers with cost-effective motor control solutions.
CL2608 DIP switch settings:
Ensure correct motor and encoder wiring; otherwise the driver will raise a position deviation alarm after receiving pulse signals at power-on.
During motor installation, never strike the rear cover to avoid damaging the encoder.
Datasheet download: 1703060332509132