CL2505

CL2505
CL2505CL2505
  • Manual Quote
Inquiry Cart
PWR 。
ALARM 。
PU+ ,+5V~+24V +24V PU- 。
PU- 。
DR+ ,+5V~+24V +24V PU- 。
DR- 。
MF+ ,+5V~+24V +24V PU- 。
MF- 。
ALM ,COM- 50mA。
PEND/Z /Z )。SW4 。 ,COM- 50mA。
BRK 100mA。
COM- 。
+5V/GND /
EZ+/EZ- /
EB+/EB- /
EA+/EA- /
A+/A- A+/A-
B+/B- B+/B-
V+/V- ,DC:+24V-50V

Description

Product Center Stepper Drivers

DUMMY

24816326412825651020254050100200PU/Rev40080016003200640012800256005120010002000400050008000100002000040000SW10ONONONONONONONONOFFOFFOFFOFFOFFOFFOFFOFFSW9ONONONONOFFOFFOFFOFFONONONONOFFOFFOFFOFFSW8ONONOFFOFFONONOFFOFFONONOFFOFFONONOFFOFFSW7ONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFSW6 OFFDefaultON3msOFF12msON40msSW5OFFOFFONONSW4PEND/Z OFF:PEND ON:Z SW3 OFF:CLOSE ON:OPEN SW2 OFF:CCW ON:CWSW1 OFF:PU&DR ON:CW&CCW

DUMMY

CL2505R communication-type closed-loop stepper driver manual (Chinese), V11.21 MB

Adopts a dedicated 32-bit motor control DSP chip and optimized closed-loop control technology

Input voltage 24–50 VDC, recommended operating voltage 36/48 V

Maximum continuous output current 5.0 A; drives size 57 and 60 closed-loop stepper motors

Input signal level compatible with 5–24 V; maximum pulse response frequency up to 500 kHz (factory default 200 kHz)

Differential inputs for pulse, direction and enable signals; supports differential, common-cathode and common-anode wiring

Common-cathode output signals: alarm, in-position, Z signal and brake control; in-position and Z signal configurable via DIP switch

Microstep DIP setting (200–51200); when all microstep switches are ON, any microstep value can be set from host software

DIP-selectable single/double pulse, open/closed-loop mode and command smoothing time

Protections: overvoltage, undervoltage, overcurrent and position deviation, etc.

10. Smooth operation with low motor noise, small overshoot and small position tracking error

The CL2505 pulse-type closed-loop stepper driver adopts the latest dedicated 32-bit motor control DSP chip and optimized closed-loop control technology. Intelligent current adjustment reduces

motor vibration and heat for longer service life; high-speed torque falloff is far lower than ordinary open-loop drivers, greatly improving high-speed performance and torque utilization, hence machine efficiency and precision. Built-in in-position, alarm and brake output signals make monitoring and control easy, and the position deviation alarm ensures safe operation of processing equipment. Two 10-position DIP switches support multiple common functions including single/double pulse, open/closed-loop mode selection and command smoothing time, making commissioning easier. Committed to providing customers with cost-effective motor control solutions.

CL2505 DIP switch settings:

Ensure correct motor and encoder wiring; otherwise the driver will raise a position deviation alarm after receiving pulse signals at power-on.

2. During motor installation, never strike the rear cover to avoid damaging the encoder.

Datasheet download: 1703060301593944

Contact Us Contact Us