| Electrical Specifications | |
|---|---|
| 12/400·Minimum supply voltage | part number with S suffix*: 50; part number without S suffix: 100 |
| 16/400·Minimum supply voltage | part number with S suffix*: 50; part number without S suffix: 100 |
| R17/400·Minimum supply voltage | part number with S suffix*: 50; part number without S suffix: 100 |
| R22/400·Minimum supply voltage | part number with S suffix*: 50; part number without S suffix: 100 |
| 8/800·Minimum supply voltage | part number with S suffix*: 95+ |
| 12/800·Minimum supply voltage | part number with S suffix*: 95+ |
| R11/800·Minimum supply voltage | part number with S suffix*: 95+ |
| R16/800·Minimum supply voltage | part number with S suffix*: 95+ |
| 12/400·Nominal supply voltage | 325 VDC |
| 16/400·Nominal supply voltage | 325 VDC |
| R17/400·Nominal supply voltage | 325 VDC |
| R22/400·Nominal supply voltage | 325 VDC |
| 8/800·Nominal supply voltage | 560 for 400 VAC, 680 for 480 VAC |
| 12/800·Nominal supply voltage | 560 for 400 VAC, 680 for 480 VAC |
| R11/800·Nominal supply voltage | 560 for 400 VAC, 680 for 480 VAC |
| R16/800·Nominal supply voltage | 560 for 400 VAC, 680 for 480 VAC |
| 12/400·Maximum supply voltage | 400 VDC |
| 16/400·Maximum supply voltage | 400 VDC |
| R17/400·Maximum supply voltage | 400 VDC |
| R22/400·Maximum supply voltage | 400 VDC |
| 8/800·Maximum supply voltage | 780 VDC |
| 12/800·Maximum supply voltage | 780 VDC |
| R11/800·Maximum supply voltage | 780 VDC |
| R16/800·Maximum supply voltage | 780 VDC |
| 12/400·Maximum continuous output power | up to 10 kW continuous rated power |
| 16/400·Maximum continuous output power | up to 10 kW continuous rated power |
| R17/400·Maximum continuous output power | up to 10 kW continuous rated power |
| R22/400·Maximum continuous output power | up to 10 kW continuous rated power |
| 8/800·Maximum continuous output power | up to 10 kW continuous rated power |
| 12/800·Maximum continuous output power | up to 10 kW continuous rated power |
| R11/800·Maximum continuous output power | up to 10 kW continuous rated power |
| R16/800·Maximum continuous output power | up to 10 kW continuous rated power |
| 12/400·Efficiency at rated power (rated conditions) | > 98 % |
| 16/400·Efficiency at rated power (rated conditions) | > 98 % |
| R17/400·Efficiency at rated power (rated conditions) | > 98 % |
| R22/400·Efficiency at rated power (rated conditions) | > 98 % |
| 8/800·Efficiency at rated power (rated conditions) | > 98 % |
| 12/800·Efficiency at rated power (rated conditions) | > 98 % |
| R11/800·Efficiency at rated power (rated conditions) | > 98 % |
| R16/800·Efficiency at rated power (rated conditions) | > 98 % |
| 12/400·Auxiliary power supply voltage selection | 18 V to 30 V S-suffix models only, for control supply |
| 16/400·Auxiliary power supply voltage selection | 18 V to 30 V S-suffix models only, for control supply |
| R17/400·Auxiliary power supply voltage selection | 18 V to 30 V S-suffix models only, for control supply |
| R22/400·Auxiliary power supply voltage selection | 18 V to 30 V S-suffix models only, for control supply |
| 8/800·Auxiliary power supply voltage selection | 18 V to 30 V S-suffix models only, for control supply |
| 12/800·Auxiliary power supply voltage selection | 18 V to 30 V S-suffix models only, for control supply |
| R11/800·Auxiliary power supply voltage selection | 18 V to 30 V S-suffix models only, for control supply |
| R16/800·Auxiliary power supply voltage selection | 18 V to 30 V S-suffix models only, for control supply |
| 12/400·Auxiliary power supply | ≤ 5 VA without external load; ≤ 8 VA with full external load |
| 16/400·Auxiliary power supply | ≤ 5 VA without external load; ≤ 8 VA with full external load |
| R17/400·Auxiliary power supply | ≤ 5 VA without external load; ≤ 8 VA with full external load |
| R22/400·Auxiliary power supply | ≤ 5 VA without external load; ≤ 8 VA with full external load |
| 8/800·Auxiliary power supply | ≤ 5 VA without external load; ≤ 8 VA with full external load |
| 12/800·Auxiliary power supply | ≤ 5 VA without external load; ≤ 8 VA with full external load |
| R11/800·Auxiliary power supply | ≤ 5 VA without external load; ≤ 8 VA with full external load |
| R16/800·Auxiliary power supply | ≤ 5 VA without external load; ≤ 8 VA with full external load |
| 12/400·Continuous current limit (Ic) sinusoidal amplitude/ DC trapezoidal commutation | 12 A |
| 16/400·Continuous current limit (Ic) sinusoidal amplitude/ DC trapezoidal commutation | 16 A |
| R17/400·Continuous current limit (Ic) sinusoidal amplitude/ DC trapezoidal commutation | 17 A |
| R22/400·Continuous current limit (Ic) sinusoidal amplitude/ DC trapezoidal commutation | 22 A |
| 8/800·Continuous current limit (Ic) sinusoidal amplitude/ DC trapezoidal commutation | 8 A |
| 12/800·Continuous current limit (Ic) sinusoidal amplitude/ DC trapezoidal commutation | 12 A |
| R11/800·Continuous current limit (Ic) sinusoidal amplitude/ DC trapezoidal commutation | 11 A |
| R16/800·Continuous current limit (Ic) sinusoidal amplitude/ DC trapezoidal commutation | 16 A |
| 12/400·Sinusoidal continuous RMS current limit (Ic) | 8.5 A |
| 16/400·Sinusoidal continuous RMS current limit (Ic) | 11.3 A |
| R17/400·Sinusoidal continuous RMS current limit (Ic) | 12 A |
| R22/400·Sinusoidal continuous RMS current limit (Ic) | 15.5 A |
| 8/800·Sinusoidal continuous RMS current limit (Ic) | 5.7 A |
| 12/800·Sinusoidal continuous RMS current limit (Ic) | 8.5 A |
| R11/800·Sinusoidal continuous RMS current limit (Ic) | 7.8 A |
| R16/800·Sinusoidal continuous RMS current limit (Ic) | 11.3 A |
| 12/400·Peak current limit | 2 x Ic |
| 16/400·Peak current limit | 2 x Ic |
| R17/400·Peak current limit | No peak |
| R22/400·Peak current limit | No peak |
| 8/800·Peak current limit | 2 x Ic |
| 12/800·Peak current limit | 2 x Ic |
| R11/800·Peak current limit | No peak |
| R16/800·Peak current limit | No peak |
| 12/400·Weight | 350 g (12.3 oz) |
| 16/400·Weight | 350 g (12.3 oz) |
| R17/400·Weight | 350 g (12.3 oz) |
| R22/400·Weight | 350 g (12.3 oz) |
| 8/800·Weight | 350 g (12.3 oz) |
| 12/800·Weight | 350 g (12.3 oz) |
| R11/800·Weight | 350 g (12.3 oz) |
| R16/800·Weight | 350 g (12.3 oz) |
| 12/400·Dimensions | 111 x 76 x 56 (4.37" x 2.99" x 2.21") |
| 16/400·Dimensions | 111 x 76 x 56 (4.37" x 2.99" x 2.21") |
| R17/400·Dimensions | 111 x 76 x 56 (4.37" x 2.99" x 2.21") |
| R22/400·Dimensions | 111 x 76 x 56 (4.37" x 2.99" x 2.21") |
| 8/800·Dimensions | 111 x 76 x 56 (4.37" x 2.99" x 2.21") |
| 12/800·Dimensions | 111 x 76 x 56 (4.37" x 2.99" x 2.21") |
| R11/800·Dimensions | 111 x 76 x 56 (4.37" x 2.99" x 2.21") |
| R16/800·Dimensions | 111 x 76 x 56 (4.37" x 2.99" x 2.21") |
| 12/400·Digital in/ Digital out/ Analog in | 6/4/1 |
| 16/400·Digital in/ Digital out/ Analog in | 6/4/1 |
| R17/400·Digital in/ Digital out/ Analog in | 6/4/1 |
| R22/400·Digital in/ Digital out/ Analog in | 6/4/1 |
| 8/800·Digital in/ Digital out/ Analog in | 6/4/1 |
| 12/800·Digital in/ Digital out/ Analog in | 6/4/1 |
| R11/800·Digital in/ Digital out/ Analog in | 6/4/1 |
| R16/800·Digital in/ Digital out/ Analog in | 6/4/1 |
| 12/400·Mounting method | Panel / wall mount |
| 16/400·Mounting method | Panel / wall mount |
| R17/400·Mounting method | Panel / wall mount |
| R22/400·Mounting method | Panel / wall mount |
| 8/800·Mounting method | Panel / wall mount |
| 12/800·Mounting method | Panel / wall mount |
| R11/800·Mounting method | Panel / wall mount |
| R16/800·Mounting method | Panel / wall mount |
Description
Overview
Ultra-compact, Stand-alone, Network Servo Drive (Up to 16 A/800 V)
Up to 10 kW of continuous power
The Solo Trombone is an ultra-compact, integrated digital servo drive that weighs 350 g (12.3 oz) and offers up to 10 kW of continuous power.
This servo drive is a SimplIQ Trombone with an integrated board that houses convenient connectors which can be used when the servo drive is not directly connected to a PCB. The Solo Trombone can also be used for testing purposes prior to integrating the Trombone into a PCB. This high power density servo drive is designed to operate “Direct to Mains” from a high voltage DC power supply of up to 400 VDC or 780 VDC, without the need for a transformer. As with all digital servo drives in the SimplIQ and Gold Lines, the Solo Trombone connects to the Gold Maestro, the ultimate distributed network motion controller .
The Trombone is truly feature-rich, combining high power density, programming flexibility, CANopen networking and numerous motion control features, resulting in a very effective solution for a wide variety of challenging applications. There are two single DC bus options: 50 – 400 VDC and 100 – 780 VDC, with a built-in smart supply for controlling the back-up capabilities. The Trombone can also operate with a 24 VDC auxiliary power supply for the back-up features.
Solo Trombone Highlights:
SimplIQ Solo Trombone Highlights:
Based on SimplIQ core motion control technology
Ultra-compact, highest power density
Supports a wide variety of feedback sensors
Vector control sinusoidal commutation
Advanced filtering and velocity gain scheduling for enhanced dynamic performance