Gold Oboe

Gold Oboe
  • Manual Quote
Inquiry Cart
Electrical Specifications
3/230·Minimum supply voltage 1 x 50 or 3 x 50 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
6/230·Minimum supply voltage 1 x 50 or 3 x 50 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
10/230·Minimum supply voltage 1 x 50 or 3 x 50 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
13/230·Minimum supply voltage 1 x 50 or 3 x 50 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
16/230onlywithLoption·Minimum supply voltage 1 x 50 or 3 x 50 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
3/230·Rated supply voltage 1 x 230 or 3 x 230 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
6/230·Rated supply voltage 1 x 230 or 3 x 230 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
10/230·Rated supply voltage 1 x 230 or 3 x 230 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
13/230·Rated supply voltage 1 x 230 or 3 x 230 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
16/230onlywithLoption·Rated supply voltage 1 x 230 or 3 x 230 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
3/230·Maximum supply voltage 1 x 270 or 3 x 270 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
6/230·Maximum supply voltage 1 x 270 or 3 x 270 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
10/230·Maximum supply voltage 1 x 270 or 3 x 270 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
13/230·Maximum supply voltage 1 x 270 or 3 x 270 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
16/230onlywithLoption·Maximum supply voltage 1 x 270 or 3 x 270 single-phase input current limited to IPhase_VAC ≤ 10 A (2–3 kW motors, 230 VAC)
3/230·Maximum continuous power output 0.8 kW
6/230·Maximum continuous power output 1.6 kW
10/230·Maximum continuous power output 2.7 kW
13/230·Maximum continuous power output 3.6 kW
16/230onlywithLoption·Maximum continuous power output 4.4 kW
3/230·Efficiency at rated power (standard conditions) > 98 %
6/230·Efficiency at rated power (standard conditions) > 98 %
10/230·Efficiency at rated power (standard conditions) > 98 %
13/230·Efficiency at rated power (standard conditions) > 98 %
16/230onlywithLoption·Efficiency at rated power (standard conditions) > 98 %
3/230·Auxiliary power supply voltage selection without fan: 18 to 30 VDC with fan: 24VDC± 10%
6/230·Auxiliary power supply voltage selection without fan: 18 to 30 VDC with fan: 24VDC± 10%
10/230·Auxiliary power supply voltage selection without fan: 18 to 30 VDC with fan: 24VDC± 10%
13/230·Auxiliary power supply voltage selection without fan: 18 to 30 VDC with fan: 24VDC± 10%
16/230onlywithLoption·Auxiliary power supply voltage selection without fan: 18 to 30 VDC with fan: 24VDC± 10%
3/230·Auxiliary power supply without fan: 6 with fan: 6(control)+ 10(fan)= 16
6/230·Auxiliary power supply without fan: 6 with fan: 6(control)+ 10(fan)= 16
10/230·Auxiliary power supply without fan: 6 with fan: 6(control)+ 10(fan)= 16
13/230·Auxiliary power supply without fan: 6 with fan: 6(control)+ 10(fan)= 16
16/230onlywithLoption·Auxiliary power supply without fan: 6 with fan: 6(control)+ 10(fan)= 16
3/230·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 3 A
6/230·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 6 A
10/230·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 10 A
13/230·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 13 A
16/230onlywithLoption·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 16 A
3/230·Continuous RMS commutation current limit (Ic) 2.1 A
6/230·Continuous RMS commutation current limit (Ic) 4.2 A
10/230·Continuous RMS commutation current limit (Ic) 7.1 A
13/230·Continuous RMS commutation current limit (Ic) 9.2 A
16/230onlywithLoption·Continuous RMS commutation current limit (Ic) 11.3 A
3/230·Peak current 6 A
6/230·Peak current 12 A
10/230·Peak current 20 A
13/230·Peak current 26 A
16/230onlywithLoption·Peak current 32 A
3/230·Built-in braking circuit (peak power) 3000 W
6/230·Built-in braking circuit (peak power) 3000 W
10/230·Built-in braking circuit (peak power) 3000 W
13/230·Built-in braking circuit (peak power) 3000 W
16/230onlywithLoption·Built-in braking circuit (peak power) 3000 W
3/480·Minimum supply voltage 3 x 140
6/480·Minimum supply voltage 3 x 140
10/480·Minimum supply voltage 3 x 140
3/480·Rated supply voltage 3 x 480
6/480·Rated supply voltage 3 x 480
10/480·Rated supply voltage 3 x 480
3/480·Maximum supply voltage 3 x 528
6/480·Maximum supply voltage 3 x 528
10/480·Maximum supply voltage 3 x 528
3/480·Maximum continuous power output 1.7 kW
6/480·Maximum continuous power output 3.5 kW
10/480·Maximum continuous power output 5.7 kW
3/480·Efficiency at rated power (standard conditions) > 98 %
6/480·Efficiency at rated power (standard conditions) > 98 %
10/480·Efficiency at rated power (standard conditions) > 98 %
3/480·Auxiliary power supply voltage selection without fan: 18 to 30 VDC with fan: 24VDC± 10%
6/480·Auxiliary power supply voltage selection without fan: 18 to 30 VDC with fan: 24VDC± 10%
10/480·Auxiliary power supply voltage selection without fan: 18 to 30 VDC with fan: 24VDC± 10%
3/480·Auxiliary power supply without fan: 6 with fan: 6(control)+ 10(fan)= 16
6/480·Auxiliary power supply without fan: 6 with fan: 6(control)+ 10(fan)= 16
10/480·Auxiliary power supply without fan: 6 with fan: 6(control)+ 10(fan)= 16
3/480·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 3 A
6/480·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 6 A
10/480·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 10 A
3/480·Continuous RMS commutation current limit (Ic) 2.1 A
6/480·Continuous RMS commutation current limit (Ic) 4.2 A
10/480·Continuous RMS commutation current limit (Ic) 7.1 A
3/480·Peak current 6 A
6/480·Peak current 12 A
10/480·Peak current 20 A
3/480·Built-in braking circuit (peak power) 2800 W
6/480·Built-in braking circuit (peak power) 2800 W
10/480·Built-in braking circuit (peak power) 2800 W
Physical Specifications
Weight Fins Heat-Sink + Fan 1.10 Kg (36.70 oz)
Dimensions Fins Heat-Sink 72.3 x 140x 109 (2.82" x 5.52" x 4.29")
Mounting method Panel / Wall Mounted
IP rating IP30
Safety
Functional safety certification IEC 61800

Description

Overview

The Smallest Servo Drive to Run 480VAC

10A/480VAC, 16A/230VAC

The Gold Oboe is a series of intelligent super compact, super-efficient servo drives that operates directly from the mains via 3-Phase or Single Phase.

With peaking capability of over 10,000W, ultra-fast response, wide bandwidth, better than 1:2000 current loop dynamic range and build in powerful regeneration the G-OBOE is a perfect servo drive for applications requiring very high dynamics, extremely precise, smooth and very low speed processing combined with rapid movements.

Integrated Smart Fan operation (in 10/230, 13/230, 6/480, 10/480 models) is activated only “when required” and thus significantly prolongs the fan’s life-time.

An auxiliary 24 VDC power supply is required to power the control and the 24VDC fan

The drives are easily set up and tuned using EASII tools software tools. This Windows-based application studio enables users to quickly and simply implement the servo drive for optimal use with the motor and the mechanical load.

Gold Oboe servo drive highlights:

Gold Oboe Highlights:

“Direct-to-mains” networking servo drive

AC input voltage of up to 3x270VAC and 3X530VAC

Gold Line core motion control technology

High Regeneration braking capability

Highly efficient ≈98%

High servo performance, wide current, velocity, position bandwidth

Real-time deterministic network communications: EtherCAT, CANopen

Host communication: USB, Ethernet

Supports a wide variety of feedback sensors in single, dual and gantry loop configurations

Advanced tuning, filtering and gain scheduling options for enhanced dynamic performance

Fast and smooth Vector control sinusoidal commutation

Easy to set up and tune with Elmo Application Studio software tools

STO, Safe Torque Off

Complies to safety, Environmental and EMC STD: IEC61800, UL508c, UL60950, EC61800-5-2

Catalog Number and Configurations

Contact Us Contact Us
Back to top