| Electrical Specifications | |
|---|---|
| 50/400·Minimum supply voltage | *For S, T or A options = 50, for 0 or 1 options = 100 |
| R100/400·Minimum supply voltage | *For S, T or A options = 50, for 0 or 1 options = 100 |
| 50/400·Rated supply voltage | 325 VDC |
| R100/400·Rated supply voltage | 325 VDC |
| 50/400·Maximum supply voltage | 400 VDC |
| R100/400·Maximum supply voltage | 400 VDC |
| 50/400·Maximum continuous power output | 16.5 kW |
| R100/400·Maximum continuous power output | 33 kW |
| 50/400·Efficiency at rated power (nominal conditions) | > 98 % |
| R100/400·Efficiency at rated power (nominal conditions) | > 98 % |
| 50/400·Auxiliary power supply voltage selection | 18 to 30VDC(S, T or A options only) |
| R100/400·Auxiliary power supply voltage selection | 18 to 30VDC(S, T or A options only) |
| 50/400·Auxiliary power supply | ≤ 5 VA without external load; ≤ 7 VA with full external load |
| R100/400·Auxiliary power supply | ≤ 5 VA without external load; ≤ 7 VA with full external load |
| 50/400·Continuous current (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 50 A |
| R100/400·Continuous current (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 100 A |
| 50/400·Peak current | 100 A |
| R100/400·Peak current | No peak |
| 50/400·Weight | 1.65 Kg (58.202 oz) |
| R100/400·Weight | 1.65 Kg (58.202 oz) |
| 50/400·Dimensions | 180 x 142 x 75.2 (7.08" x 5.53" x 2.96") |
| R100/400·Dimensions | 180 x 142 x 75.2 (7.08" x 5.53" x 2.96") |
| 50/400·Digital in/Digital out/Analog in | 6/4/1 |
| R100/400·Digital in/Digital out/Analog in | 6/4/1 |
| 50/400·Mounting method | Flat / wall mount |
| R100/400·Mounting method | Flat / wall mount |
| 35/800·Minimum supply voltage | *For S, T or A options = 95 |
| 50/800·Minimum supply voltage | *For S, T or A options = 95 |
| R70/800·Minimum supply voltage | *For S, T or A options = 95 |
| R100/800·Minimum supply voltage | *For S, T or A options = 95 |
| 35/800·Rated supply voltage | 560 for 400 VAC 680 for 480 VAC |
| 50/800·Rated supply voltage | 560 for 400 VAC 680 for 480 VAC |
| R70/800·Rated supply voltage | 560 for 400 VAC 680 for 480 VAC |
| R100/800·Rated supply voltage | 560 for 400 VAC 680 for 480 VAC |
| 35/800·Maximum supply voltage | 780 VDC |
| 50/800·Maximum supply voltage | 780 VDC |
| R70/800·Maximum supply voltage | 780 VDC |
| R100/800·Maximum supply voltage | 780 VDC |
| 35/800·Maximum continuous power output | 22.5 kW |
| 50/800·Maximum continuous power output | 32.5 kW |
| R70/800·Maximum continuous power output | 45 kW |
| R100/800·Maximum continuous power output | 65 kW |
| 35/800·Efficiency at rated power (nominal conditions) | > 98 % |
| 50/800·Efficiency at rated power (nominal conditions) | > 98 % |
| R70/800·Efficiency at rated power (nominal conditions) | > 98 % |
| R100/800·Efficiency at rated power (nominal conditions) | > 98 % |
| 35/800·Auxiliary power supply voltage selection | 18 to 30VDC(S, T or A options only) |
| 50/800·Auxiliary power supply voltage selection | 18 to 30VDC(S, T or A options only) |
| R70/800·Auxiliary power supply voltage selection | 18 to 30VDC(S, T or A options only) |
| R100/800·Auxiliary power supply voltage selection | 18 to 30VDC(S, T or A options only) |
| 35/800·Auxiliary power supply | ≤ 5 VA without external load; ≤ 7 VA with full external load |
| 50/800·Auxiliary power supply | ≤ 5 VA without external load; ≤ 7 VA with full external load |
| R70/800·Auxiliary power supply | ≤ 5 VA without external load; ≤ 7 VA with full external load |
| R100/800·Auxiliary power supply | ≤ 5 VA without external load; ≤ 7 VA with full external load |
| 35/800·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 35 A |
| 50/800·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 50 A |
| R70/800·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 70 A |
| R100/800·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 100 A |
| 35/800·Continuous RMS sinusoidal commutation current limit (Ic) | 25 A |
| 50/800·Continuous RMS sinusoidal commutation current limit (Ic) | 35 A |
| R70/800·Continuous RMS sinusoidal commutation current limit (Ic) | 50 A |
| R100/800·Continuous RMS sinusoidal commutation current limit (Ic) | 71 A |
| 35/800·Peak current | 70 A |
| 50/800·Peak current | 100 A |
| R70/800·Peak current | No peak |
| R100/800·Peak current | No peak |
| 35/800·Weight | 1.65 Kg (58.202 oz) |
| 50/800·Weight | 1.65 Kg (58.202 oz) |
| R70/800·Weight | 1.65 Kg (58.202 oz) |
| R100/800·Weight | 1.65 Kg (58.202 oz) |
| 35/800·Dimensions | 180 x 142 x 75.2 (7.08" x 5.53" x 2.96") |
| 50/800·Dimensions | 180 x 142 x 75.2 (7.08" x 5.53" x 2.96") |
| R70/800·Dimensions | 180 x 142 x 75.2 (7.08" x 5.53" x 2.96") |
| R100/800·Dimensions | 180 x 142 x 75.2 (7.08" x 5.53" x 2.96") |
| 35/800·Digital in/Digital out/Analog in | 6/4/1 |
| 50/800·Digital in/Digital out/Analog in | 6/4/1 |
| R70/800·Digital in/Digital out/Analog in | 6/4/1 |
| R100/800·Digital in/Digital out/Analog in | 6/4/1 |
| 35/800·Mounting method | Flat / wall mount |
| 50/800·Mounting method | Flat / wall mount |
| R70/800·Mounting method | Flat / wall mount |
| R100/800·Mounting method | Flat / wall mount |
| Safety | |
| Functional safety certification | IEC 61800 |
Description
Overview
High Power Super Compact, Direct to Mains, Network-Based Servo Drive (Up to 65 kW)
The Gold Drum HV 100 A/800 V is the highest power Gold Servo Drive. Designed to operate “Direct to Mains” from a rectified 480 VAC (+10%).
The Gold DRUM HV meets the highest level of motion control application requirements, providing top servo performance, advanced networking, built-in safety and high power density, combined with a fully featured motion controller and local intelligence.
In conjunction with Elmo’s Gold Maestro, the ultimate distributed network motion controller, and the other members of Elmo’s Gold Line of intelligent servo drives , state-of-the-art solutions for the most challenging multi-axis motion applications can be easily implemented, with a short development cycle.
Read our application note on Thermal Management to discover how to achieve efficient, cost-saving heat dissipation while using the Gold Drum HV.
Gold Drum HV Highlights:
Gold Drum HV Highlights:
Gold Line core motion control technology
Ultra-compact, highest power density
Highly efficient ≈99%
High servo performance, wide current, velocity, position bandwidth
Real-time deterministic network communications: EtherCAT, CANopen
Host communication: USB, Ethernet
Supports a wide variety of feedback sensors in single, dual and gantry loop configurations
Advanced tuning, filtering and gain scheduling options for enhanced dynamic performance
Vector control sinusoidal commutation
Easy to set up and tune with Elmo Application Studio software tools
Windows-based application enables users to quickly and simply configure the servo drive for optimal use with their motor
Complies to safety and EMC STD: IEC61800, UL508c, UL60950, EC61800-5-2
EtherCAT slave drives with rotary switches allow the user to define a unique node ID to a slave
The two rotary switches offer up to 255 addresses, with the 0 setting referring to No alias address
Catalog Number and Configurations