Gold Drum HV

Gold Drum HV
  • Manual Quote
Inquiry Cart
Electrical Specifications
50/400·Minimum supply voltage *For S, T or A options = 50, for 0 or 1 options = 100
R100/400·Minimum supply voltage *For S, T or A options = 50, for 0 or 1 options = 100
50/400·Rated supply voltage 325 VDC
R100/400·Rated supply voltage 325 VDC
50/400·Maximum supply voltage 400 VDC
R100/400·Maximum supply voltage 400 VDC
50/400·Maximum continuous power output 16.5 kW
R100/400·Maximum continuous power output 33 kW
50/400·Efficiency at rated power (nominal conditions) > 98 %
R100/400·Efficiency at rated power (nominal conditions) > 98 %
50/400·Auxiliary power supply voltage selection 18 to 30VDC(S, T or A options only)
R100/400·Auxiliary power supply voltage selection 18 to 30VDC(S, T or A options only)
50/400·Auxiliary power supply ≤ 5 VA without external load; ≤ 7 VA with full external load
R100/400·Auxiliary power supply ≤ 5 VA without external load; ≤ 7 VA with full external load
50/400·Continuous current (Ic) sinusoidal amplitude/ trapezoidal DC commutation 50 A
R100/400·Continuous current (Ic) sinusoidal amplitude/ trapezoidal DC commutation 100 A
50/400·Peak current 100 A
R100/400·Peak current No peak
50/400·Weight 1.65 Kg (58.202 oz)
R100/400·Weight 1.65 Kg (58.202 oz)
50/400·Dimensions 180 x 142 x 75.2 (7.08" x 5.53" x 2.96")
R100/400·Dimensions 180 x 142 x 75.2 (7.08" x 5.53" x 2.96")
50/400·Digital in/Digital out/Analog in 6/4/1
R100/400·Digital in/Digital out/Analog in 6/4/1
50/400·Mounting method Flat / wall mount
R100/400·Mounting method Flat / wall mount
35/800·Minimum supply voltage *For S, T or A options = 95
50/800·Minimum supply voltage *For S, T or A options = 95
R70/800·Minimum supply voltage *For S, T or A options = 95
R100/800·Minimum supply voltage *For S, T or A options = 95
35/800·Rated supply voltage 560 for 400 VAC 680 for 480 VAC
50/800·Rated supply voltage 560 for 400 VAC 680 for 480 VAC
R70/800·Rated supply voltage 560 for 400 VAC 680 for 480 VAC
R100/800·Rated supply voltage 560 for 400 VAC 680 for 480 VAC
35/800·Maximum supply voltage 780 VDC
50/800·Maximum supply voltage 780 VDC
R70/800·Maximum supply voltage 780 VDC
R100/800·Maximum supply voltage 780 VDC
35/800·Maximum continuous power output 22.5 kW
50/800·Maximum continuous power output 32.5 kW
R70/800·Maximum continuous power output 45 kW
R100/800·Maximum continuous power output 65 kW
35/800·Efficiency at rated power (nominal conditions) > 98 %
50/800·Efficiency at rated power (nominal conditions) > 98 %
R70/800·Efficiency at rated power (nominal conditions) > 98 %
R100/800·Efficiency at rated power (nominal conditions) > 98 %
35/800·Auxiliary power supply voltage selection 18 to 30VDC(S, T or A options only)
50/800·Auxiliary power supply voltage selection 18 to 30VDC(S, T or A options only)
R70/800·Auxiliary power supply voltage selection 18 to 30VDC(S, T or A options only)
R100/800·Auxiliary power supply voltage selection 18 to 30VDC(S, T or A options only)
35/800·Auxiliary power supply ≤ 5 VA without external load; ≤ 7 VA with full external load
50/800·Auxiliary power supply ≤ 5 VA without external load; ≤ 7 VA with full external load
R70/800·Auxiliary power supply ≤ 5 VA without external load; ≤ 7 VA with full external load
R100/800·Auxiliary power supply ≤ 5 VA without external load; ≤ 7 VA with full external load
35/800·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 35 A
50/800·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 50 A
R70/800·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 70 A
R100/800·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation 100 A
35/800·Continuous RMS sinusoidal commutation current limit (Ic) 25 A
50/800·Continuous RMS sinusoidal commutation current limit (Ic) 35 A
R70/800·Continuous RMS sinusoidal commutation current limit (Ic) 50 A
R100/800·Continuous RMS sinusoidal commutation current limit (Ic) 71 A
35/800·Peak current 70 A
50/800·Peak current 100 A
R70/800·Peak current No peak
R100/800·Peak current No peak
35/800·Weight 1.65 Kg (58.202 oz)
50/800·Weight 1.65 Kg (58.202 oz)
R70/800·Weight 1.65 Kg (58.202 oz)
R100/800·Weight 1.65 Kg (58.202 oz)
35/800·Dimensions 180 x 142 x 75.2 (7.08" x 5.53" x 2.96")
50/800·Dimensions 180 x 142 x 75.2 (7.08" x 5.53" x 2.96")
R70/800·Dimensions 180 x 142 x 75.2 (7.08" x 5.53" x 2.96")
R100/800·Dimensions 180 x 142 x 75.2 (7.08" x 5.53" x 2.96")
35/800·Digital in/Digital out/Analog in 6/4/1
50/800·Digital in/Digital out/Analog in 6/4/1
R70/800·Digital in/Digital out/Analog in 6/4/1
R100/800·Digital in/Digital out/Analog in 6/4/1
35/800·Mounting method Flat / wall mount
50/800·Mounting method Flat / wall mount
R70/800·Mounting method Flat / wall mount
R100/800·Mounting method Flat / wall mount
Safety
Functional safety certification IEC 61800

Description

Overview

High Power Super Compact, Direct to Mains, Network-Based Servo Drive (Up to 65 kW)

The Gold Drum HV 100 A/800 V is the highest power Gold Servo Drive. Designed to operate “Direct to Mains” from a rectified 480 VAC (+10%).

The Gold DRUM HV meets the highest level of motion control application requirements, providing top servo performance, advanced networking, built-in safety and high power density, combined with a fully featured motion controller and local intelligence.

In conjunction with Elmo’s Gold Maestro, the ultimate distributed network motion controller, and the other members of Elmo’s Gold Line of intelligent servo drives , state-of-the-art solutions for the most challenging multi-axis motion applications can be easily implemented, with a short development cycle.

Read our application note on Thermal Management to discover how to achieve efficient, cost-saving heat dissipation while using the Gold Drum HV.

Gold Drum HV Highlights:

Gold Drum HV Highlights:

Gold Line core motion control technology

Ultra-compact, highest power density

Highly efficient ≈99%

High servo performance, wide current, velocity, position bandwidth

Real-time deterministic network communications: EtherCAT, CANopen

Host communication: USB, Ethernet

Supports a wide variety of feedback sensors in single, dual and gantry loop configurations

Advanced tuning, filtering and gain scheduling options for enhanced dynamic performance

Vector control sinusoidal commutation

Easy to set up and tune with Elmo Application Studio software tools

Windows-based application enables users to quickly and simply configure the servo drive for optimal use with their motor

Complies to safety and EMC STD: IEC61800, UL508c, UL60950, EC61800-5-2

EtherCAT slave drives with rotary switches allow the user to define a unique node ID to a slave

The two rotary switches offer up to 255 addresses, with the 0 setting referring to No alias address

Catalog Number and Configurations

Contact Us Contact Us
Back to top