Gold Bassoon
- Manual Quote
| Electrical Specifications | |
|---|---|
| 3/230·Minimum supply voltage | 1 x 50 or 3 x 50 |
| 6/230·Minimum supply voltage | 1 x 50 or 3 x 50 |
| 10/230·Minimum supply voltage | 1 x 50 or 3 x 50 |
| 3/230·Rated supply voltage | 1 x 230 or 3 x 230 |
| 6/230·Rated supply voltage | 1 x 230 or 3 x 230 |
| 10/230·Rated supply voltage | 1 x 230 or 3 x 230 |
| 3/230·Maximum supply voltage | 1 x 270 or 3 x 270 |
| 6/230·Maximum supply voltage | 1 x 270 or 3 x 270 |
| 10/230·Maximum supply voltage | 1 x 270 or 3 x 270 |
| 3/230·Maximum continuous power output | 0.95 kW |
| 6/230·Maximum continuous power output | 1.9 kW |
| 10/230·Maximum continuous power output | 3.25 kW |
| 3/230·Efficiency at rated power (standard conditions) | > 98 % |
| 6/230·Efficiency at rated power (standard conditions) | > 98 % |
| 10/230·Efficiency at rated power (standard conditions) | > 98 % |
| 3/230·Auxiliary power supply voltage selection | without fan: 18 to 30 VDC with fan: 24VDC± 10% |
| 6/230·Auxiliary power supply voltage selection | without fan: 18 to 30 VDC with fan: 24VDC± 10% |
| 10/230·Auxiliary power supply voltage selection | without fan: 18 to 30 VDC with fan: 24VDC± 10% |
| 3/230·Auxiliary power supply | without fan: 6 with fan: 6(control)+ 10(fan)= 16 |
| 6/230·Auxiliary power supply | without fan: 6 with fan: 6(control)+ 10(fan)= 16 |
| 10/230·Auxiliary power supply | without fan: 6 with fan: 6(control)+ 10(fan)= 16 |
| 3/230·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 3 A |
| 6/230·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 6 A |
| 10/230·Continuous current limit (Ic) sinusoidal amplitude/ trapezoidal DC commutation | 10 A |
| 3/230·Continuous RMS commutation current limit (Ic) | 2.1 A |
| 6/230·Continuous RMS commutation current limit (Ic) | 4.2 A |
| 10/230·Continuous RMS commutation current limit (Ic) | 7.1 A |
| 3/230·Peak current | 6 A |
| 6/230·Peak current | 12 A |
| 10/230·Peak current | 20 A |
| 3/230·Built-in braking circuit (peak power) | 3000 W |
| 6/230·Built-in braking circuit (peak power) | 3000 W |
| 10/230·Built-in braking circuit (peak power) | 3000 W |
| Safety | |
| Functional safety certification | IEC 61800 |
Description
Overview
10A, 230VAC Ultra Compact Servo Drive
The Gold Bassoon is an advanced high power density servo drive that provides top servo performance delivering up to 3200 Watts (6400 Watts peak).
The Gold Bassoon operates from an AC power source of 30VAC- 270VAC, single or 3 Phases.
The G-BAS drive can operate as a stand-alone device or as part of a multi-axis system in a distributed configuration on a real-time network.
The Gold Bassoon is available in a variety of options. There are multiple power rating options, two different communications options, a variety of feedback selections and I/O configuration possibilities.
The drives are easily set up and tuned using Elmo Application Studio software tools. This Windows-based application enables users to quickly and simply configure the servo drive for optimal use with their motor.
An auxiliary 24 VDC power supply is required.
The Smart Fan operation (in 10A models) is activated only “when required” and thus significantly prolonging the fan’s life-time.
Gold Bassoon Servo Drive Highlights:
Gold Bassoon Highlights:
“Direct-to-mains” networking servo drive
Rectifies AC input voltage of up to 3x270VAC
Gold Line core motion control technology
High Regeneration braking capability
Ultra-compact, highest power density
Highly efficient ≈98%
High servo performance, wide current, velocity, position bandwidth
Continuous output current: 3A, 6A,10A.
Extra ordinary current loop dynamic range of 2000:1
Real-time deterministic network communications: EtherCAT, CANopen
Host communication: USB, Ethernet
Supports a wide variety of feedback sensors in single, dual and gantry loop configurations
Advanced tuning, filtering and gain scheduling options for enhanced dynamic performance
Vector control sinusoidal commutation
Easy to set up and tune with Elmo Application Studio software tools
STO, Safe Torque Off
Complies to safety, Environmental and EMC STD: IEC61800, UL508c, UL60950, EC61800-5-2
Catalog Number and Configurations